Introduction: When a clerk at a convenience store was placing a glass
quart bottle of beer into the cooler it "exploded" and a piece of glass went
into his eye. The challenge was to determine the cause of the failure.
Procedure: The bottle was assembled and the approximate location of the
crack initiation site was located. This location was then examined with a low
power microscope, and the crack origin was documented.
Results: This was a delayed failure that was initiated at a time prior to the
final failure. At some point prior to the accident the barrel of the bottle had
been bruised. This is demonstrated by the "mirror" failure at the origin (Figure
#1). Parts of the origin were missing; however, there was enough of it to
determine the cause. In addition to the initial mirror, there are three crack
arrest lines that indicate that this particular failure had started and stopped
several times before the final break (Figure #2).
Conclusion: This failure was initiated at some point before the final
failure that caused the eye injury.

Arrow Indicates
Mirror Initiation Site: This is on the outer surface of the bottle.
Figure #1: Fracture Initiation Site: The failure initiated at a bruise on the
outer barrel of the one quart bottle. The initial impact created the mirror
fracture at the top of the picture (Magnification 15X).

Arrow Indicates Crack Arrest Lines
Figure #2: higher Magnification of the Crack Initiation Site. Here there are
several crack arrest lines that indicate that this failure was initiated at some
time prior to the final failure and injury (Magnification 40X).
|